Edge Detection

Detect potentially harmful edges within a defined zone.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

The Edge Detection App is located in the Analysis tab of the Fuzor App Menu. The Alt + I hotkey opens the Edge Detection App. This is a good way to ensure that there are no hazardous areas in your model that could be an issue during construction.

The Barrier Height sets a height for the barrier.

The Initial Spacing defines an interval to check over.

The Drop Threshold sets the maximum distance of an unmarked edge.

The Worker Height defines the height of the worker.

The Barrier Radius defines the radius of the barrier.

The Show markers and Show Edges check boxes will toggle whether these are displayed in the 3D view. Edges highlight along dangerous edges, whereas markers highlight the beginning and ends of dangerous edges.

The Calculate button begins the edge detection analysis with the current settings.

The Report button generates an edge detection report with the current settings

The Reset button resets the edge detection settings to their defaults.

Zones are used to confine the test within a space. A zone must be selected in the zone list in order to be calculated.